- Conformity to Community Directives: 2014/35/UE 2006/42/CE
- Conformity to Standards: EN 60204-1 EN 60947-1 EN 60947-5-1 EN 60529 ISO 13850.
- Storage ambient temperature: -40°C/+70°C
- Operational ambient temperature: -25°C/+70°C
- Protection degree: IP 65Insulation category: Class II
- Cable entry: Cable gland M20 / Spiral cable gland M20
- Operating positions: any position
- Weight: ~ 320 g
- Markings and homologations: CE EAC
- Utilisation category: AC 15
- Rated operational current: 3 A
- Rated operational voltage: 250 V
- Rated thermal current: 10 A
- Rated insulation voltage: 500 V~
- Mechanical life: 0.5×106 operations
- Connections: screw-type terminals
- Wires: 1×2.5 mm², 2×1.5 mm² (UL – (c)UL: use 60°C or 75°C copper (CU) conductor and wire 16-18 AWG)
- Tightening torque: 0.6 Nm
- Markings and homologations: CE cULus EAC
Downloads
Charlie Control Pendant BrochureDescription
Compact-sized pendant station for auxiliary control. Modern user-friendly design, developed by an industrial design firm on technical, anthropomorphic, futuristic and ergonomic specifications. Easy to handle and designed to reduce installation time and costs and maintenance down time.
Features
- Reduced time and costs for installation and wiring: the switches are assembled inside the pendant station without
screws, with all the terminals facing the cable inlet and screws in the opposite direction to facilitate wiring. - A threaded ring is used to secure the enclosure and cover, providing easy access to the internal components without any need for tools or screws.
- Thanks to the hollow handle the control station can be quickly and easily set down onto a pin.
- The emergency stop mushroom pushbutton complies with standard EN 418.
- Mechanical life of switches: 1 million operations.
- IP protection degree: Charlie is classified IP65.
- Extreme temperature resistance: -25°C to +70°C.
- All materials and components used are wear resistant and guarantee protection of the unit against water and dust.
Options
- Available in configuration with 2 or 3 actuators.
- Single switches with NO or NC contacts and double switches with NO contacts, one or two speeds, with electrical interlock to prevent simultaneous operation of opposite functions.